Web Analytics

Inficon Hapsite ER Portable GC-MS

Inficon Hapsite ER Portable GC-MS

$0.00

HAPSITE ER is the only person-portable Gas Chromatograph/Mass Spectrometer (GC/MS) that requires minimal training to deliver qualitative and quantitative lab-quality results in the field in less than 10 minutes. Quick, Easy, Accurate On-Site Performance. Quick, easy, and accurate on-site performance at the click of a button, measuring volatile organic compounds (VOCs), toxic industrial chemicals (TICs), toxic industrial materials (TIMs), chemical warfare agents (CWAs), and select semi-volatile organic compounds (SVOCs).

HAPSITE ER has the capability to identify analytes in the PPM (parts-per-million) – PPT (parts-per-trillion) range. The GC column provides sharp chromatography and excellent resolution. During the quantitation method, the front panel clearly displays what chemicals are present, their concentration, and access to information regarding the degree of danger – to help make quick decisions affecting life, health, and safety.

HAPSITE ER is the only person-portable Gas Chromatograph/Mass Spectrometer (GC/MS) that requires minimal training to deliver qualitative and quantitative lab-quality results in the field in less than 10 minutes. Quick, Easy, Accurate On-Site Performance. Quick, easy, and accurate on-site performance at the click of a button, measuring volatile organic compounds (VOCs), toxic industrial chemicals (TICs), toxic industrial materials (TIMs), chemical warfare agents (CWAs), and select semi-volatile organic compounds (SVOCs).

HAPSITE ER has the capability to identify analytes in the PPM (parts-per-million) – PPT (parts-per-trillion) range. The GC column provides sharp chromatography and excellent resolution. During the quantitation method, the front panel clearly displays what chemicals are present, their concentration, and access to information regarding the degree of danger – to help make quick decisions affecting life, health, and safety.

CleanAir offers for sale both disposable replacement cylinders for the HAPSITE:

Disposable Internal Standard Gas Cylinder for Inficon Hapsite
Disposable Carrier Gas Cylinder for Inficon Hapsite

Features

  • Fast, confirmatory results in the field directly comparable to laboratory GC/MS data
  • Universal interface allows for accessory expansion without a hardware change to HAPSITE
  • Simple operation for even basic skill levels with minimal training
  • Visual confirmation of correct probe placement for optimum sample collection
  • Clear, color indicators of sample identity and level of danger
  • Pre-programmed methods to obtain quality data in minutes with a few simple keystrokes
  • Bright, graphical display of chromatograms, spectra, and instrument status for easy viewing
  • Built-in GPS records exact sampling location for legally defensible data

Specs

Operating Temperature °C 5 to 45
L x W x H in. 18 x 17 x 7
Weight (with battery): 42 lb
Power Supply: Rechargeable NiMH battery pack or AC converter
Battery Life: 2-3 hr.
Power Requirement: 24V DC
Hard Drive: 16 GB Solid State Flash Drive
Flash Drive USB
Display in. 6.5 VGA color display with touch screen
Sample Introduction Air probe (included) or optional accessory
Carrier Gas Nitrogen
Data System Intel® Pentium® processor
Communication 802.11G wireless or direct Ethernet connection
Data Analysis AMDIS Mass Spectral Libraries, NIOSH, (NIST on optional laptop)
Sample Type VOCs and select SVOCs
Detection Limit PPT for most analytes
Mass Spectrometer
Mass Range amu 41-300 (1-300 using SIM)
Scan Rate Scan Rate 1000 AMU/sec @ 10 points per AMU
Ionization Mode eV 70
Detector Detector Electron Multiplier
Vacuum System Vacuum System Non Evaporable Getter (NEG) Pump
Dynamic Range decades 7
Gas Chromatograph
GC Column GC Column 15 m, db-1MS, 0.25 mm i.d., 1.0 um df (standard)
Temperature Range °C 45-200

CleanAir offers for sale both disposable replacement cylinders for the HAPSITE:

Disposable Internal Standard Gas Cylinder for Inficon Hapsite
Disposable Carrier Gas Cylinder for Inficon Hapsite

Part Number Description
070-860-2 HAPSITE ER Training Kit, XINF-19-KIT
930-242-G1 NEG Pump, factory installed
930-477-P1 Gas Combo Pack
930-705-G1 Sample Loop Kit
930-425-P1 Spare Non Evaporable Getter (NEG) Pump
930-205-G1 Ionizer w/Magnet, Hapsite Smart Plus
930-4062-G1 Hapsite Battery
930-432-P6 Canister, Carrier Gas, 6 each
930-432-P12 Canister, Carrier Gas, 12 each
930-433-P6 Canister, Internal Standard, 6 each
930-433-P12 Canister, Internal Standard, 12 each
930-432-P24 Canister, Carrier Gas, 24 each
930-730-G1 Extended Life Carrier Gas Deployment Kit
930-4611-P1 Extended Life Carrier Gas
930-716-G1 Concentrator, Tri-Bed Kit
930-251-G1 Concentrator, Tenax Kit
930-249-G2 Concentrator Cover
930-0221-G1 Concentrator Tube Nut and Ferrule Kit
930-250-G1 Sample Loop Cover
071-747 Performance Standard Concentrator / Air
071-748 Chemical Kit, Performance/IS
071-760 Chemical Standards Kit, HAPSITE
070-1686 Sample Bag, 1 Liter, ALTEF, 10 pack
070-1419 Sample Bag, Vacu-Tube, 0.7 Liter,10 each
070-1224 Gastight Syringe 50 mL, w/Luer Lock
070-1205 Gastight Syringe, 25 mL
070-1206 Gastight Syringe, 10 μl
070-1207 Replacement Needle, 10 μl
070-1223 10 μl Syringe, 6 pack
070-1420 Vacu-Tube, 0.7 Liter
070-1454 Syringe, 1L, w/Luer Lock

Headspace Sampling System
Thermal Desorber Sampling System
Solid Phase Microextraction (SPME) Sampling System
Service Module
SituProbe Sampling System

Brochure (English)
Manual (English)
Guide: Keeping the HAPSITE Deployable Ready

CleanAir Engineering provides world-class service, support, and technical expertise alongside every instrument rental. All air monitoring equipment is inspected or calibrated before shipping from one of our four technical centers. Each rental includes additional accessories and components, providing added convenience and reliability to ensure the success of your project. Contact us for more information.

CleanAir Engineering offers full-service calibration or repair for this item. To learn more, contact a technician today at: 1-800-553-5511. Or, complete our repair request form to begin your service request today! Most out-of-calibration or out-of-service instruments can be shipped to any one of our four technical service centers, in Chicago, Houston, Pittsburgh, or Marseille, France.