Aeroqual S500 Handheld Custom Kit
$0.00
Portable and accurate real time air quality information made affordable.
The Outdoor Air Quality Test Kit (Pro) is for consultants and air quality professionals who want a full set of tools to measure a range of common pollutants in ambient outdoor air. The Outdoor Air Quality Test Kit (Pro) features Aeroqual’s proven Series 500 portable monitor that can be used to measure a range of pollutants by simply swapping the sensor heads for the pollutant you wish to monitor. The kit includes the following sensors: particulate matter sensor (PM2.5/PM10), four gas pollutant gas sensors (NO2, O3, CO, VOC), and a combined temperature and relative humidity sensor. Now you can perform full outdoor air quality assessments using instruments tried and proven by researchers and air quality professionals around the world.
- Series 500 Monitor base including: LCD digital display, Lithium battery and charger, in-built datalogger, monitor to USB cable, PC software.
- Particulate Matter Sensor PM10 / PM2.5
- Select 4 Sensors
- Temperature & Humidity Sensor
- Large Carry Case
Benefits
- Complete outdoor air quality monitoring kit for measurement of criteria air pollutants and VOCs
- Series 500 monitor with inbuilt real-time data logger
- Active fan sampling sensor heads (PM2.5/PM10, NO2, O3, CO, VOC) ensure high accuracy measurements
- Zero and span calibrate sensors in the field
- Long life lithium battery technology
- Connect direct to PC via USB
- Free PC software (Windows 7 and above)
- By adding the optional outdoor enclosure can be left in situ for short term monitoring
Applications
- Wide area air quality surveys
- Checking pollution “hotspots”
- Personal exposure monitoring
- Short term fixed monitoring networks
Step 1 – Gather data
Use the monitor and interchangeable sensors to take spot measurements, or log data over time and space. The monitor is designed to fit comfortably in the hand and the long life lithium battery gives you a full day in the field.
Step 2 – Download data
Using the Series 500 model, connect to a PC and download your measurements using Aeroqual’s free software. Data can be exported to Excel. The Series 300 and 500 models can also output data directly via 0-5V and RS232.
Step 3 – Analyze data
Analyze your data to identify trends, discover leaks or pollution hotspots, or dive deep into the numbers for research. Data can be tagged to a location, and data is tied to the individual monitor ID. This makes large studies, involving multiple monitors and locations, easy to manage.
Other Products from Aeroqual
All sensors use active fan sampling
Measurements | Formula | Range (ppm) | Accuracy | Resolution (ppm) | Sensor Type | Part Number |
---|---|---|---|---|---|---|
Ammonia | NH3 | 0-100 | <±0.5ppm + 10% | 0.1 | GSE | SHENG |
Ammonia | NH3 | 0-1000 | <±5 ppm +15% | 1 | GSS | SHNH |
Carbon Dioxide | CO2 | 0-2000 | <±10ppm + 5% | 1 | NDIR | SHCD |
Carbon Dioxide | CO2 | 0-5000 | <±20ppm + 5% | 1 | NDIR | SHCE |
Carbon Monoxide (Leak Detector) |
CO | 0-1000 | <±2ppm + 15% | 1 | GSS | SHCO |
Carbon Monoxide | CO | 0-25 | <±0.5 ppm 0-5 ppm <±10% 5-25ppm |
0.01 | GSE | SHECM |
Carbon Monoxide | CO | 0-100 | <±1 ppm 0-10 ppm <±10% 10-100ppm |
0.1 | GSS | SHECN |
Chlorine | Cl2 | 0-10 | <±0.02ppm + 10% | 0.01 | GSE | SHECL |
Formaldehyde | CH2O | 0-10 | <±0.05 ppm 0-0.5 ppm <±10% 0.5-10ppm |
0.01 | GSE | SHEF |
Hydrogen | H2 | 0-5000 | <±10ppm + 10% | 1 | GSS | SHHA |
Hydrogen sulfide | H2S | 0-10 | <±0.05 ppm 0-0.5 ppm <±10% 0.5-10ppm |
0.01 | GSE | SHEHS |
Hydrogen sulfide | H2S | 0-100 | <±0.5 ppm 0-5 ppm <±10% 5-100ppm |
0.1 | GSE | SHEHT |
Methane | CH4 | 0-10,000 | <±20ppm + 15% | 1 | GSS | SHMT |
Nitrogen Dioxide | NO2 | 0-1 | <±0.02 ppm 0-0.2 ppm <±10% 0.2-1 ppm |
0.001 | GSE | SHENW |
Nonmethane Hydrocarbons | NMHC | 0-25 | <±0.1 ppm + 10% | 0.1 | GSS | SHVN |
Ozone | O3 | 0-10 | <±0.01ppm + 7.5% | 0.01 | GSE | SHEOZ |
Ozone | O3 | 0-10 | <±0.1ppm + 15% | 0.01 | GSS | SHOZG |
Ozone | O3 | 0-0.5 | <±0.008 ppm 0-0.1 ppm <±10% 0.1-0.5 ppm |
0.001 | GSS | SHOZL |
Ozone | O3 | 0-0.15 | <±0.005 ppm | 0.001 | GSS | SHOZU |
Ozone | O3 | 0-0.05 | <±0.002 ppm | 0.001 | GSS | SHOZS |
Particulate Matter | PM with RH Correction | 0.001-1.000 µg /m3 | ± 0.005 µg /m3 + 15 % | 0.001 µg /m3 | LPC | SHPM |
Perchloroethylene | C2Cl4 | 0-200 | <±5 ppm 0-50 ppm <±10% 50-200 ppm |
1 | GSS | SHPE |
Sulfur Dioxide | SO2 | 0-10 | <±0.05 ppm 0-0.5 ppm <±10% 0.5-10ppm |
0.01 | GSE | SHESO |
Sulfur Dioxide | SO2 | 0-100 | <±0.5 ppm 0-5 ppm <±10% 5-100ppm |
0.1 | GSE | SHESP |
Volatile Organic Compounds | VOC | 0-2000 | <±0.2ppm + 10% | <1000ppm: 0.1 >1000ppm: 1 |
PID | SHVOCH |
Volatile Organic Compounds | VOC | 0-30 | <±0.02ppm + 10% | 0.01 | PID | SHVOC |
Volatile Organic Compounds | VOC | 0-25 | <±0.1 ppm + 10% | 0.1 | GSS | SHVM |
Volatile Organic Compounds | VOC | 0-500 | <±5ppm + 10% | 1 | GSS | SHVP |
Sensor Types
|
Part Number | Item |
---|---|
AERO-HHS500L | Monitor base with lithium battery and power pack, alarms, data-logging and PC Software |
AERO-HHTRH | Plug-in temperature and RH sensor for Series 300, and 500 monitors |
AERO-HHENC | Water- and dust-proof enclosure for Series 300 and 500 |
AERO-ASR10 | Remote sensor kit for Series 300/500 remote location measurement |
AERO-ASR13 | Remote sensor kit for Series 300/500 remote location measurement (NEMA 2/IP41) |
AERO-ASR32 | Cigarette lighter adapter for handheld monitors (Lithium/NiMH compatible) |
AERO-ASR33 | Bracket for wall-mounting handheld monitors |
AERO-ASR36 | Replacement Lithium battery (blue) for handheld monitors |
AERO-ASR40 | Protective carry case for a Series 300/500 monitor plus four gas sensor heads |
AERO-ASR41 | Robust case with shoulder strap for Series 300/500 monitor plus eight gas sensor heads |
AERO-ASR42 | Calibration accessory for handheld monitors |