CleanAir Heated Sample Line
$0.00 – $6,628.50
Each CleanAir Engineering Heated Sample Line features an electrically heat-traced and insulated 3/8″ PTFE (.030 Wall) sample line with a stainless steel over-braid and stainless steel tube ends, a 1/4 PTFE (.040 wall) calibration line, 3-pin Amphenol power connector, and two type-K thermocouple plugs. Protected by a durable scuff-resistant, extruded polyurethane jacket. Also available to rent.
Each CleanAir Engineering Heated Sample Line features an electrically heat-traced and insulated 3/8″ PTFE (.030 Wall) sample line with a stainless steel over-braid and stainless steel tube ends, a 1/4 PTFE (.040 wall) calibration line, 3-pin Amphenol power connector, and two type-K thermocouple plugs. Protected by a durable scuff-resistant, extruded polyurethane jacket. Also available to rent.
Heated Sample Lines are not self-limiting; a temperature controller is required. Sold separately.
Custom lengths, voltage, and configurations available.
Part Number | Volts | Watts | Length (Ft.) / Description | Amps |
---|---|---|---|---|
0723-10 | 120 | 300 | 10′ Heated Sample Line | 2.73 |
0723-25 | 120 | 750 | 25′ Heated Sample Line | 6.82 |
0723-50 | 120 | 1500 | 50′ Heated Sample Line | 13.64 |
0723-100 | 120 | 2500 | 100′ Heated Sample Line | 22.73 |
*0723-100HD | 120 | 3000 | 100′ Heavy Duty Heated Sample Line* | 27 |
0723-100220 | 120/240 | 100′ Dual Voltage Heated Sample Line | ||
0725RENT | CleanAir HSL Universal Temperature Controller | |||
0725R | CleanAir Rack-Mount HSL Universal Temperature Controller | |||
0725—PE | Heated Sample Line Power Extension |
* Heavy Duty Heated Sample Lines are manufactured for a continuous operating temperature of 400°F (~204°C) at -20°F ambient temperature.
Features
- Lower resistance heaters require less power to heat lines.
- A backup type-K thermocouple to prevent project delays in the case of primary thermocouple failure in the field.
- Stainless steel over-braid and stainless steel tube ends help prevent abrasive failure in the field.
- Optional: stainless steel over-braid for calibration line
- Durable, extruded polyurethane jacket for protection of sample/calibration lines from abrasive failure in the field.
- Inert PTFE sample and calibration lines provide more accurate results by eliminating potential bias from other materials. PTFE is also more corrosion-resistant than Tygon, and can be washed with acetone without degradation.
Temperature Ratings
Heavy Duty (HD) Heated Sample Lines are manufactured to have a continuous operating temperature of 400° F (~204° C) at an ambient temperature of -20° F. Triple-Insulated to help maintain line temperature with lower power consumption.
Standard Heated Sample Lines are manufactured to have a continuous operating temperature of 400° F (~204° C) at an ambient temperature of 0° F.